Scenario 6 Set Output Relays
Select Detector Interface and Route Relays:
1) Click the Detector Interface button to select
the type of detector/controller interface to be
used ( BIU #1 SDLC ).
2) Click the Ph- button to select Phase group
5L. Note that the line zones corresponding to
the selected phase group turn green. All others
are magenta.
3) Click the D button to select the detector
channel ( D7) this phase is routed to in the
SDLC message.
4) Click the Ext= and the Dly= to select the
Detection Extension in seconds and the
Detection Delay in seconds.
5) Click N, Or, And button to select logic for
combining (N=Not Used) Phase Groups into
Detector Channels.
6) To clear the settings for the selected Phase
group or for all Phase groups click the Clear or
the Clear All button.
1
2
3
6
4
BIU #1 SDLC Detector/Controller Interface with 3 Phases (Line Zone Groups)
Phase 5L, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D7
Phase 2T, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D8
Phase 2R, Detection Delay=2 sec, Detection Extension=0, Route to Detector Channel D8
5
Specifies Routing to Onboard Output Relay
Connector (1, 2, .., 10 0-Disables) for shelf
mount SVS-1